Your home has a lot of appliances that need repair and maintenance. Without it, energy costs and repair bills will increase. Faulty plumbing and malfunctioning HVAC systems are also unsafe. And that’s where we can help.
Since 1926, Classic Aire Care has provided exceptional HVAC and plumbing services in Ballwin.
Our NATE-certified technicians are background-checked and carefully vetted. With 24/7 emergency repair service available, we can tackle the biggest or smallest home repair issue.
Expert Air Conditioning Services
With summers hazy, hot, and humid in Ballwin, your AC is under demand to perform. Whether you need repair work or want to upgrade your unit, we can help. Our AC services include:
- AC Repairs: Our technicians service all brands and offer same-day service. Common issues include insufficient cooling, strange noises, and cycling problems. Our Planned Maintenance Agreement includes exclusive savings like 15% off our repairs.
- AC Maintenance: Routine service can extend your air conditioner’s life span and reduce repair costs. Let our technicians inspect your system and make any necessary repairs.
- AC Replacement: Older air conditioners can lose their efficiency. Let us recommend the best replacement that fits your needs and lower your energy costs by up to 30%! Ask us about improving indoor air quality and cost-saving, ductless mini-split systems.
Get a free estimate on a new AC in Ballwin by calling Classic Aire Care at (314) 329-1943.
Dependable Heating Services
Winters can be brutal in Missouri, and when the temperature drops below freezing, your furnace or heat pump should provide toasty warm heat in every room. If your HVAC is not working, or you want to upgrade to a more efficient version, turn to us. Our heating services include:
- Heating repair: Our technicians are available 24 hours if your heater is underperforming. With our vehicles stocked, we will efficiently and quickly make repairs.
- Heating replacement: Replace your older heater with a modern version and decrease utility costs. With tax credits available, the savings add up!
- Heating maintenance: Regular tune-ups mean fewer emergency repairs. Schedule biannual maintenance to keep your HVAC working at peak performance.
Your Local Plumbing Experts
Your home’s plumbing can include outdated and corroded pipes that eventually need repair or replacement. Our plumbing installation and replacement solutions include water heater replacement for corrosion, loss of heat, or leaks.
Our tankless replacements provide an endless hot water supply, while our backflow preventer replacements will keep your water contaminant-free. Rely on our professionals for plumbing repairs like water problems (disposals, toilet leaks, clogged drains, low faucet pressure), or burst or leaking pipes.
Schedule same-day plumbing service in Ballwin by calling Classic Aire Care at (314) 329-1943.
Why Choose Classic Aire Care?
At Classic Aire Care, we’ve been making people comfortable since 1926! Our NATE-Certified technicians are dedicated to your comfort, and we guarantee superior workmanship and solutions you can depend on. When you choose our team, you will always enjoy:
- 100% satisfaction guarantee on installations
- Classic ultimate quality guarantee
- Free estimates
- Exceptional service agreements
- 24 hours a day, 7 days a week emergency service
- And more!Â
Call Classic Aire Care at (314) 329-1943 for same-day repairs in Ballwin.
FAQs
Why is my AC running but not cooling?
Your AC has several components that operate independently; if the evaporator coils freeze or something compromises a heat exchanger, you’ll get air, but it won’t be cool. If the blower breaks, you’ll have cool refrigerant in place but no air blowing it out.
How often should I schedule HVAC maintenance?
As a general rule, you should have your home’s HVAC system inspected and serviced at least once a year. Twice a year (once for heating and once for cooling) would be ideal.
What are the signs that I need to replace my HVAC system?
Frequent breakdowns, rising energy bills, and fluctuating indoor temperatures are all strong signs that it’s time for an HVAC system replacement.
How can I improve my home's indoor air quality?
Keep the house well-ventilated by opening the windows and using fans. You can also use air purification devices, and avoid smoking or using products that contain volatile organic compounds (VOCs).
What should I do if I have a clogged drain?
Try using a plunger or a chemical drain cleaner. If that doesn’t work, it’s best to call a professional plumber.
Have you Seen Us in Ballwin?
Classic Aire Care’s van with the family of penguins is easily one of the most recognizable vehicles in St. Louis. Below is a map showing where our family of penguins have been recently!Â
Recent Jobs and Reviews in Ballwin, MO
Job Locations and Reviews
Responded to no-cool call on residential air conditioning unit less than 10 years old located in side yard. Upon arrival, confirmed customer report of warm air from supply registers and observed frozen evaporator coil. Advised customer to turn unit off at thermostat and set fan to continuous operation to facilitate ice melting. Inspected refrigerant lines, condensate drain system, and equipment mounting components. Documented existing installation configuration including suction and liquid line routing, condensate drain piping, and equipment pad condition. Unit requires follow-up visit after coil has fully thawed to diagnose root cause of freezing condition, which may include restricted airflow due to dirty filter or blocked return, low refrigerant charge from potential leak, failed blower motor or capacitor, or malfunctioning metering device. Customer instructed to monitor system and schedule diagnostic appointment once ice has completely melted.
Completed comprehensive tune-up service on two 6-year-old outdoor AC units per Home Depot work order. Performed standard maintenance procedures including inspection of control board and electrical connections, verified proper wiring integrity across all terminal blocks and relays, and assessed air filtration media condition. Both systems were found in functional operating condition with all components operating within normal parameters.
Completed preventative maintenance tune-up on outdoor condensing unit located at side of home. Upon inspection, found significant accumulation of dirt, dust, and debris throughout electrical compartment and on internal components. Performed thorough cleaning of condenser coil, checked all electrical connections, tested TITAN PRO capacitor for proper microfarad reading and voltage, inspected contactor operation, and verified compressor amperage draw. All wiring connections secured and system returned to normal operating condition with satisfactory cooling performance.
Completed comprehensive tune-up service on a 10-year-old residential air conditioning system located on the side of the home. Performed standard maintenance procedures on the outdoor condenser unit and indoor evaporator coil, including inspection of all major components, electrical connections, and refrigerant levels. Noted moderate dust and debris accumulation on the evaporator coil fins, which was addressed during the maintenance service to restore optimal airflow and heat exchange efficiency.
Completed cooling system tune-up on 13-year-old outdoor AC unit. Inspected and replaced dirty air filter, cleaned condenser coil fins which had accumulated significant debris and organic material between the fins affecting heat transfer efficiency. System operational upon completion of preventative maintenance service.
Completed cooling season tune-up on a 12-year-old ground-mounted air conditioning unit. Performed comprehensive maintenance inspection including checking refrigerant levels, cleaning condenser coils, testing electrical connections, verifying proper airflow, and ensuring optimal system operation. Unit is functioning properly with no issues identified during service.
Completed comprehensive tune-up on a 2-year-old residential air conditioning unit located in the backyard. System inspection revealed heavily soiled condenser coils with significant accumulation of dirt, dust, and debris throughout the heat exchanger fins, which was thoroughly cleaned to restore optimal heat transfer efficiency. Replaced dirty air filter with fresh media to ensure proper airflow and system performance.
Completed comprehensive cooling maintenance tune-up on a 15-year-old air conditioning system. Performed full system inspection including electrical components, capacitor testing, refrigerant level verification, and cleaning of condenser unit. All components found operating within normal parameters; system confirmed working properly upon completion.
Completed cooling system tune-up on single residential unit located in side yard. Performed comprehensive maintenance inspection revealing significant debris and dirt accumulation on evaporator coil fins, particularly in lower sections with dark discoloration indicating restricted airflow. Inspected electrical components, control boards, and wiring connections within unit compartment; all connections secure and functioning properly. Verified proper refrigerant line integrity and system operation. Unit is under 10 years old and operational following service.
Completed comprehensive tune-up service on an 11-year-old ground-mounted air conditioning unit. Performed standard preventive maintenance including inspection of electrical components, capacitor testing, verification of proper wiring connections, and assessment of overall system operation. All components found to be functioning within normal parameters, and unit was cleared for continued operation.
Completed installation of LED lighting fixtures in kitchen area. Installed 8-12 new LED light fixtures in soffit space above cabinetry, providing enhanced illumination for the workspace. All fixtures tested and confirmed operational upon completion.
Performed preventive seasonal cooling check on a 13-year-old American Standard air conditioning system. Inspected interior components of air handler unit, verifying electrical connections, control boards, and wiring harness integrity. Evaluated 20x25x1 air filter condition and replaced with new filter to ensure proper airflow and system efficiency. All electrical components, circuit boards, and connections found in satisfactory operating condition with no immediate concerns noted.
Installed soft start kit on HVAC unit to reduce compressor startup current and improve system efficiency. Replaced failed capacitor under warranty with van stock unit, ensuring proper electrical connections and secure mounting within the equipment cabinet. System tested and verified operational for both heating and cooling modes upon completion.
Responded to no cooling call on 2001 Lennox air conditioning system. Upon arrival, performed diagnostic testing using digital manifold gauges and clamp meter to assess system performance. Measured refrigerant pressures showing 289 PSIG on high side and 93.2 PSIG on low side, along with electrical readings of 90.5 amps, indicating potential compressor or refrigerant charge issues requiring further evaluation and repair.
Responded to service call for 6-year-old outdoor AC unit that would not turn off automatically. Inspected thermostat wiring and control board connections, then examined outdoor unit components including contactor, capacitor, and relay switch. Diagnosed faulty contactor preventing proper system shutdown when thermostat reached setpoint. Replaced defective contactor, verified proper voltage readings, and tested system through multiple cooling cycles to confirm unit now responds correctly to thermostat commands and shuts off as programmed.
Conducted comprehensive site assessment and provided detailed estimate for whole home surge protection system and standby generator installation. Evaluated existing electrical panel configuration, documenting current circuit breaker arrangement and wire routing to determine compatibility with proposed surge protection device and generator transfer switch integration. Assessed panel capacity, available breaker spaces, and existing wire management to establish installation requirements and identify any necessary panel modifications or upgrades to accommodate new equipment.
Responded to service call for 13-year-old ground-level unit blowing warm air and running constantly. Upon arrival, measured amperage draw at 12.36 amps using clamp meter to verify compressor operation. Advised customer to turn unit off at thermostat and run fan only mode until issue could be properly diagnosed and resolved.
Responded to intermittent tripping issue affecting air conditioning unit at older electrical panel located in basement. Performed comprehensive inspection of main breaker panel and exterior meter base, evaluating breaker conditions, bus bar connections, and overall panel integrity. Documented panel configuration and exterior service entrance components with photographic evidence for assessment of aging electrical infrastructure and potential upgrade recommendations.
Completed electrical estimate for outlet expansion in storage room and garage workspace. Storage room assessment identified existing two-outlet configuration with accessible open stud wall adjacent to shared wall containing multiple outlets, providing straightforward access for splicing additional 2-3 receptacles to eliminate extension cord dependency. Garage evaluation focused on workbench area requiring additional power outlets, with customer accepting GFCI protection for ungrounded circuit installation where equipment ground unavailable.
Completed comprehensive cooling tune-up on 6-year-old residential air conditioning system located in backyard. Performed full system inspection including electrical connections, control board functionality, blower assembly, and ductwork integrity. All components found operating within normal parameters; system tested and confirmed ready for cooling season. --- Performed preventative maintenance tune-up on single air conditioning unit. Inspection revealed clean electrical connections with properly secured wire bundles, functional control board with operational relays and contactors, and intact blower housing. Examined interior components including circuit board, wiring harness, and flexible duct connections. Verified all safety controls and electrical systems functioning correctly. Unit tested and left in proper working condition with no immediate service needs identified.